4.2  H - Bridge & Voltage Multiplier at low Voltage

4.2.1  Simulation model and measurement set-up

The measurement set-up is shown in Figure 4.11. (A) is the power supply for the electronic, B the oscilloscope to capture the voltages, C an isolating transformer for G, D is the inductor (paragraph 3.3, E the voltage multiplier, F the H-Bridge and G the DC supply for the H - Bridge.

 

Figure 4.11: Measurement Set-up

Figure 4.12 shows the PSpice simulation schematic of the combined H ‑ Bridge and Voltage Multiplier.

 

Figure 4.12: PSpice Schematic: H-Bridge & Voltage Multiplier

 

This page is part of a Frameset: Electrodynamic Sculpture: A Thesis by Rafael Bräg.